Jamstvo : 24 mjeseca , – UPServer 2.0 series is is the ultimate solution to protect Server and Data Center
– It has an output power capability of 2000VA, which is suited to supply 90% of the critical loads in IT applications
– It may be configured either in rack or tower version and is based on a On-Line double conversion DSP (Digital Signal Processor) technology
– UPServer 2.0 may increase its autonomy time by adding battery packs
– USB, RS232 communication ports and filtered RJ45 port are available by default
– EPO contact is present by default, too. SNMP card and Realy card are available as option. Input and Output with IEC cables are connected for an easy and quick installation
– UPServer 2.0 is the best cost effective solution for your IT system

TECHNICAL DATA
INPUT DATA
– Power: 2000 VA / 1350W
– Voltage: 230V
– Selectable Input Voltage
: 200V/208V/220V/230V/240V
– Voltage range at 100% load: 160 – 290 Vac
– Nominal Frequency: 50/60 Hz auto-sensing
– Frequency range: 45–55Hz (50Hz)/55-65Hz (60Hz) before switching to battery
– Bypass voltage range:
* +5%,+10%,+15%,+25% (+25% by default)
* -20%,-30%,-45%(-45% by default)
– Battery Voltage: IEC320 C13-10A
– Power UPS: IEC320 C14-10A

OUTPUT DATA
– Nominal value: 200/208/220/230/240V (programmable or auto-sensing)
– Frequency: 50 or 60 Hz, auto-sensing
– Overload (Normal operation):
* 108% +/-5% – 150% +/-5%: Load transfers to Fault mode after 30 sec
* 150% +/-5% – 200% +/-5%: Load transfers to Fault mode after 300 msec.
* >200% +/-5%: Load transfers to Fault mode after 20 msec.
– Overload (Bypass mode):
* 100% +/-5% – 130% +/-5%: UPS switch to Fault after 20′
* 130% + /-5% – 150% +/-5%: UPS switch to Fault after 2′
* 150% +/-5% – 200% +/-5%: UPS switch to Fault after 15sec.
* >200% +/-5%: UPS switch to Fault after 140 ms.
– Overload (Battery mode):
* 108% +/-5% – 150% +/-5%: UPS switch to Fault after 30 sec.
* 150% +/-5% – 200% +/-5%: switch to Fault after 300 ms.
* >200% +/-5%: UPS switch to Fault after 20 ms.
– Output waveform: Sinusoidal
– Harmonic distortion:
* <3% THD with linear load * <5% THD with non linear load - Switching time: * Online mode: 0 ms * ECO mode : 10ms max. - Crest Factor: 3 a 1 ELECTRIC - 2× IEC C13-10A + 1 Shuko - Cable: IEC320 C14-10A STANDARD AND OPTIONAL COMMUNICATION PORTS - Optional card to insert into the slot: SNMP card or clean contacts Relay - Standard communication port: RS232 (DB-9): 2400bps USB DIMENSIONS / WEIGHT - Dimension (W×D×H): 440×430×86.5 mm - Weight: 15.7 kg ENVIRONMENT AND SAFETY - Overvoltage suppression: * EN 61000-2-2 * EN 61000-4-2, level 4 * EN 61000-4-3, level 3 * EN 61000-4-4, level 4 * EN 6100-4-5, level 4 Criteria A - EMC certification: CE per IEC/EN 62040-2, Classe B - EMC (Emission): IEC 62040-2:ed2:2005 / EN 62040-2:2006 - Safety: IEC 62040-1-1, IEC 60950-1 - Marking: CE, CB - Operating Temperature: 0C to 40C (32F to 104F) with variation according to altitude * internal thermal sensor shall switch the load to bypass in case of overtemperature - Humidity: 0–90% without condensation - Operating Altitude: Up to 3.000 meters (9.843 ft) above sea level - Noise level: <55 dBA a 1 metro typ - Leakage current: <1.5 mA